current location:home pageProduct Center

53502(F71B1) 53602B(F71B3)

Instructions Download>

Model

53502(F71B1)

Regeneration

Time clock type/Meter Type

Installation

Top-mounted

Inlet/outlet

3/4" M

Drain

3/4" M

Base

2.5"-8NPSM

Riser pipe

1.05" OD

Water treatment capacity

2 m³/h

Tank diameter range

6"~10"

Water pressure

0.15MPa0.6MPa

Water temperature

5℃50℃

Water turbidity

20FTU

Power adapter

Input AC100240V/5060Hz

Output DC12V/1.5A

Application

Activated carbon filter; Sand filter

Filter media

Quartz sand; Activated carbon


Product description

Product Characteristics

  • Simple structure and reliable sealing

    It adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, and Fast Rinse.

  • No water pass the valve in rinsing in single tank type

  • Manual function

    Realize rinsing immediately by pressing “Manual/Return” at any time.

  • Long outage indicator

    If outage overrides 3days, the time of day indicator “12:12”will flash to remind people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.

  • LED dynamic screen display

    The stripe on dynamic screen flash, it indicates the control valve is in service; otherwise, it is in rinsing cycle.

  • Buttons lock

    No operations to buttons on the controller within 1 minute, button lock indicator light on which represent buttons are locked. Before operation,press and hold the “Up”and“Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.

  • Rinsing frequency

    It could set up multiple rinsing times, which means several times of backwash and fast rinse but one time of service. It is much better for cleaning the filter materials.

  • All parameters can be modified

    According to the water quality and usage, the parameters can be adjusted.

  • It can choose meter type or time clock type

  • Remote handling input

    This connector can receive external signal, used together with PLC, and computer etc. to control the valve.

  • Interlock function

    It has a function of interlock to realize only one valve in rinsing, but the other valves are in service while there are several valves parallel in system. In multi-steps treatment systems such as RO pre-treatment, when several valves are in series, there is only one valve in rinsing to ensure pass water all the times while different valves in rinsing.