current location:home page > Product Center
Model | F79A-LCD/F70D(82602/41202), F79B-LCD/F70D(82602B/41202) |
Inlet/outlet | 3/4"M |
Drain | 1/2"M |
Brine line connector | 3/8"M |
Mounting base | 2.5"-8NPSM |
Riser pipe | 1.05"OD |
Flow rate | 2m³/h |
Filter tank | 6"--18" |
Water pressure | 0.15-0.6Mpa |
Water temperature | 5-50℃ |
Water turbidity | Down-flow regeneration<5FTU;Up-flow regeneration<2FTU;Filtration<20FTU |
Ambient temperature | 5-50℃ |
Relative humidity | ≤95%(25℃) |
Power adapter | Input AC100~240V/50~60HZ Output DC12V/1.5A |
F79 Residential Water Softener Valves
Featuring a flow rate of 2m³/h, the F79 achieves different functions, including service, backwash, brine& slow rinse, brine refill and fast rinse through parameter modifications.
The F79 is a multifunctional softening valve, where up-flow regeneration, down-flow regeneration are all accomplished. The F79 is also furnished with an F70D bypass valve, allowing for original water passage during the regeneration process.
Simple structure and reliable sealing
It adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse.
Manual function
Realize regeneration immediately by pushing manual button at any time.
Long outage indicator
If outage overrides 3days, the time of day indicator “” will flash to remind people to reset new time of day. (Refer to the figure)
LCD screen display
Adopt wordage to display all status, clear and briefly.
Users can choose English or Chinese display interface in 2 ways:
A. Connecting power then press buttons “Menu/Confirm” and “Manual/Return” for five seconds to enter language choice interface.
B. Enter into “Set Language” to choose the language.
Buttons lock
No operations to buttons on the controller within 1 minute, button lock indicator light on which represent buttons are locked. Before operation press and hold the “Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.
The F79 with weather cover can be installed outside
Has water bypass and no hard water bypass two choices
No hard water bypass refers to the control valve no water pass when valve in regeneration. Model: A for no hard water bypass (No raw water flow out from outlet when in regeneration process); B for with hard water bypass. (With raw water flow out from outlet when in regeneration process)
With partial bypass function
Service time, by adjusting bypass screw can let part of raw water flow into the outlet without being softened.
Down-flow regeneration, up-flow regeneration and filter can be implemented with a valve.
By program selection to choose following modes
Mode | Name | Instruction |
A-01 | Down-flow Regeneration, Meter Delayed | Down-flow regeneration, regenerate on the day although the available volume of treated water drops to zero (0). Regeneration starts at the regeneration time. |
A-02 | Down-flow Regeneration, Meter Immediate | Down-flow regeneration, regenerate when the available volume of treated water drops to zero (0). |
A-03 | Down-flow Regeneration, Intelligent Meter Type | Down-flow regeneration, regenerate starts at the regeneration time of the current day when the available volume of treated water less than the average water consumption of last 7 days. |
A-11 | Up-flow Regeneration, Meter Delayed | Up-flow regeneration, regenerate starts at the regeneration time although the available volume water of treated water drops to zero (0). Regeneration starts at the regeneration time. |
A-12 | Up-flow Regeneration, Meter Immediate | Up-flow regeneration, regenerate when the available volume of treated water drops to zero (0). |
A-13 | Up-flow Regeneration, Intelligent Meter Type | Up-flow regeneration, regeneration starts at the regeneration time of the current day when the available volume of treated water less than the average water consumption of last 7 days. |
A-21 | Filter Type | Filter type, filter when the service days or available capacity reach to zero (0) |
Interval backwash times (Only for up-flow regeneration valve)
It could set up interval backwash times for up-flow type A-11, 12, 13, which means several times of services but one time of backwash. The setting of interval backwash time is depending on the local water turbidity. (The lower the turbidity is, the longer of the interval backwash time can be set)
Rinsing frequence
It could set up rinsing frequence when selection of filter mode A-21, which means several times of backwash and fast rinse but one time of service (Need set). In this mode, the brine line connector need be sucked in this working mode.