current location:home pageProduct Center

17610_F88A

Instructions Download>

Model

F88A17610

Inlet/outlet

1.5"M

Drain

1"M

Brine line connector

1/2"M

Mounting base

1.5"M top and bottom distributor basket

Flow rate

10m³/h

Filter tank

20"--30"

Mount type

Two tanks: one in service, one for standby

Water pressure

0.15-0.6Mpa

Water temperature

5-50

Water turbidity

2FTU

Ambient temperature

5-50

Relative humidity

≤95%25

Power adapter

Input AC100~240V/50~60HZ Output DC24V/1.5A

Application

Ion exchange equipment, water treatment system, RO pretreatment system


Product description

F88A Twin Alternating Softener Configuration

With a flow rate of 10m³/h, the F88A carries out service, backwash brine and slow rinse, brine refill, and a fast rinse through a simple parameter modification.

Product Characteristics

  • Simple structure and reliable sealing

    It adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash(Settling Bed), Brine & Slow Rinse, Brine Refill and Fast Rinse.

  • One Valve for dual purpose

    When you install the valve, set up the drain port toward left it becomes valve 93610, toward right it becomes valve 17610(17606). When the valve power on, hold and press buttons “Menu/Confirm” and “Manual/Return” for 5 seconds can enter the program choice mode, use “Up” or “Down” to select program and then press “Menu/Confirm” to confirm.

  • Meter type, one valve double tank supply water uninterruptedly

  • Manual function

    Realize regeneration immediately by pushing “Manual/Return” at any time.

  • Long outage indicator

    If outage overrides 3 days, the time of day indicator “12:12” will flash to remind to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.

  • LED dynamic screen display

    The stripe on dynamic screen flash, it indicates the control valve is in service position, otherwise, it is in regeneration cycle.

  • Button lock

    No operations to buttons on the controller within 1 minute, button lock indicator light on which represents buttons are locked. Before operation, press and hold the “Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.