Product description

Product Characteristics


  • Simple structure and reliable sealing

    It adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Settling Bed, Brine & Slow Rinse, Brine Refill and Fast Rinse.

  • No water pass the valve in regeneration in single tank type.

  • Manual function

    Realize regeneration immediately by pushing manual button “Manual/Return” at any time.

  • Long outage indicator

    If outage overrides 3days, the time of day indicator “12:12”will flash to remind people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.

  • LED dynamic screen display

    The stripe on dynamic screen flash, it indicates the control valve is in service, otherwise, it is in regeneration cycle.

  • Buttons lock

    No operations to buttons on the controller within 1 minute, button lock indicator light on which represent buttons are locked. Before operation press and hold the “Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.

  • Four kinds of meter type can be selected (Suite for F83A3)

Model

Name

Instruction

A-01

Meter Delayed

Regenerate on the day although the available volume of treated water drops to zero (0). Regeneration starts at the regeneration time.

A-02

Meter Immediate

Regenerate immediately when the available volume of treated water drops to zero(0).

A-03

Intelligent Meter Delayed

Meter Delayed Regeneration type, but by setting Resin Volume, Feed Water Hardness, Regeneration Factor, the controller will calculate the System Capacity.

A-04

Intelligent Meter Immediate

Meter Immediately Regeneration Type, but by setting Resin Volume, Feed Water Hardness, Regeneration Factor, the controller will calculate the System Capacity.

  • Interchange of time clock type and meter type

    When valve is set as time clock type (Such as F83A1), through dialing a blue switch (Refer to Figure 1) to transfer it to be meter type. “ON” indicate meter type, “1” indicate time clock type. (Note: After dialing the switch, valve shall restart.)

  • Interlock function

It has a function of interlock to realize only one valve in regeneration but the other valves are in service while several valves parallel in system. In multi-steps treatment systems such as RO pre-treatment, when several valves are in series, there is only one valve in regeneration or washing to ensure pass water all the times.