65503(F117Q1) 65603(F117Q3)

Instructions Download>

Model

F117Q1/Q365503/65603

Regeneration

Time clock type / meter type

Mount type

Top mount

Inlet/outlet

3/4" F

Drain

3/4" M

Brine line connector

3/8"M

Mounting base

2.5"-8NPSM

Riser pipe

1.05"OD

Flow rate

3m³/h

Filter tank

6"--12"

Water pressure

0.15-0.6MPa

Water temperature

5-50℃

Water turbidity

Down-flow regeneration5FTU

Power adapter

Input AC100~240V/50~60HZ Output DC12V/1.5A


Product description

F117Q Automatic Multiport Softener Valves

Featuring a flow rate of 3m³/h, the F117Q1/Q3 automatic multiport softener valve adopts a planar and corrosion resistant gasket for opening and closing. The different functions such as service, backwash, brine and slow rinse, brine refill and fast rinse can be realized through parameters modification. The F117Q1 is a timer clock type while F117 Q3 is a meter type.

Product Characteristics

  • Simple structure and reliable sealing

    The distribution valve adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, Brine & Slow Rinse, Fast Rinse and Brine Refill.

  • No water pass the valve in regeneration in single tank type.

  • Manual function

    Realize regeneration immediately by pushing manual button “Manual/Return” at any time.

  • Long outage indicator

    If outage overrides 3 days, the time of day indicator “12:12” will flash to remind people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.

  • The valve will automatically rotate for more than ten seconds after it is electrified

    After the valve is electrified, it will automatically rotate for more than ten seconds to turn back to the position when the electricity is cut off.

  • Buttons lock

    No operations to buttons on the controller within 1 minute, button lock indicator lights on which represents buttons are locked. Before operation, press and hold the “Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.

  • Interval backwash times (Suitable for F68Q/F69Q)

    It could set up interval backwash times for F68Q/F69Q up-flow regeneration valve, which means several times of services but one time of backwash. The setting of interval backwash times depends on the local water turbidity. (The lower the turbidity is, the longer of the interval backwash times can be set)

  • It can choose time clock type or meter type by program selection

    When all symbols light on, press and hold “Manual/Return” and “Menu/Confirm” buttons for 5 seconds to enter the menu of valve model selection. Please set the program type in accordance with the product type. (Tim clock type by days or meter type) (Notice: The meter type product has one flow meter and flow meter cable, but the time clock type does not ).