Model | F117Q1/Q3(65503/65603) |
Regeneration | Time clock type / meter type |
Mount type | Top mount |
Inlet/outlet | 3/4" F |
Drain | 3/4" M |
Brine line connector | 3/8"M |
Mounting base | 2.5"-8NPSM |
Riser pipe | 1.05"OD |
Flow rate | 3m³/h |
Filter tank | 6"--12" |
Water pressure | 0.15-0.6MPa |
Water temperature | 5-50℃ |
Water turbidity | Down-flow regeneration<5FTU |
Power adapter | Input AC100~240V/50~60HZ Output DC12V/1.5A |
F117Q Automatic Multiport Softener Valves
Featuring a flow rate of 3m³/h, the F117Q1/Q3 automatic multiport softener valve adopts a planar and corrosion resistant gasket for opening and closing. The different functions such as service, backwash, brine and slow rinse, brine refill and fast rinse can be realized through parameters modification. The F117Q1 is a timer clock type while F117 Q3 is a meter type.
Simple structure and reliable sealing
The distribution valve adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, Brine & Slow Rinse, Fast Rinse and Brine Refill.
No water pass the valve in regeneration in single tank type.
Manual function
Realize regeneration immediately by pushing manual button “Manual/Return” at any time.
Long outage indicator
If outage overrides 3 days, the time of day indicator “12:12” will flash to remind people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.
The valve will automatically rotate for more than ten seconds after it is electrified
After the valve is electrified, it will automatically rotate for more than ten seconds to turn back to the position when the electricity is cut off.
Buttons lock
No operations to buttons on the controller within 1 minute, button lock indicator lights on which represents buttons are locked. Before operation, press and hold the “Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.
Interval backwash times (Suitable for F68Q/F69Q)
It could set up interval backwash times for F68Q/F69Q up-flow regeneration valve, which means several times of services but one time of backwash. The setting of interval backwash times depends on the local water turbidity. (The lower the turbidity is, the longer of the interval backwash times can be set)
It can choose time clock type or meter type by program selection
When all symbols light on, press and hold “Manual/Return” and “Menu/Confirm” buttons for 5 seconds to enter the menu of valve model selection. Please set the program type in accordance with the product type. (Tim clock type by days or meter type) (Notice: The meter type product has one flow meter and flow meter cable, but the time clock type does not ).