current location:home pageProduct Center

51202C(F56EC)

Instructions Download>

Model

51102C(F56EC)

Inlet/outlet

1/2" F or 3/4" F

Drain

1/2" F or 3/4" F

Base

2.5"-8NPSM

Riser pipe

1.05" OD

Water treatment capacity

2 m³/h

Tank diameter range

6"`~10"

Water pressure

0.15MPa0.6MPa

Water temperature

5℃50℃

Water turbidity

20FTU

Environment temperature

550

Relative Humidity

95(25℃)


Product description

System Configuration and Flow Rate Parameters

Tank size

Activated Carbon Filter

Sand Filter

Diameter

Height

Tank Volume

Filter Material

Volume

Filter Flow Rate

Backwash

Flow Rate

Filter

Flow Rate

Backwash

Flow Rate

in

mm

in

L

L

m3/h

m3/h

m3/h

m3/h

6

152

35

14.4

10

0.2

0.7

0.4

1.0

7

178

44

25.4

17

0.3

0.9

0.6

1.3

8

203

44

32.9

22

0.4

1.1

0.8

1.7

9

229

48

44.7

30

0.5

1.5

1.0

2.2

10

254

54

65.3

41

0.6

1.7

1.2

2.6

12

305

65

89.2

59

0.8

2.5

1.7

3.8

13

330

54

113.8

69

1.0

3.0

2.1

4.6

14

356

65

150.3

103

1.2

3.4

2.4

5.2

16

406

65

189.6

120

1.5

4.5

3.1

6.8

18

457

65

253

169

2.0

5.9

4.1

8.8

20

508

72

310.5

207

2.4

7.0

4.9

10.6

22

550

72

385

255

2.8

8.5

5.9

12.8

24

610

88

480

320

3.4

10.0

7.0

15.2

Note: The listed activated carbon filter flow rate is outcome of calculation based on a flow velocity of 12m/h; The backwash rate is based on a backwash intensity of 10L/(㎡*s). The above sand filter flow rate correspond s to a flow velocity of 25m/h; The backwash rate is related to a backwash intensity of 15L/(㎡*s)