53515(F99B1) 53615(F99B3)

Instructions Download>

Model

F99B1/B353515/53615

Regeneration

Time clock type / meter type

Mount type

Top mount / side mount

Inlet/outlet

2"M

Drain

2"M

Mounting base

4"-8UN

Riser pipe

1.5"D-GB

Flow rate

15m³/h

Filter tank

14"--30"

Water pressure

0.2-0.6MPa

Water temperature

5-50℃

Water turbidity

20FTU

Power adapter

Input AC100~240V/50~60HZ Output DC24V/1.5A

Application

Manganese and RO pretreatment

Filter media

Quartz sand, activated carbon


Product description

F99B1/B3 Automatic Multiport Filter Valves

Delivering a flow rate of 15m³/h, the F99B1/B3 automatic multiport filter valves can complete service, backwash, and fast rinse functions through simple parameter modifications. It adopts a planar and corrosion resistant gasket for opening and closing. The F99B1 is a timer clock type valve while the F99B3 is a meter type.

Product Characteristics

  • Simple structure and reliable sealing

    It adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, Brine Draw, Slow Rinse, Fast Rinse and Brine Refill.

  • No water passes the valve during regeneration in single tank type

  • Brine refill is controlled by electronic ball valve

    During service, electronic ball valve will control to start the brine refill so as to shorten the regeneration cycle time. 63515/63615 brine refilled with hard water, 73515/73615 brine refilled with soft water.

  • Variety of installation methods

    Use side-mounted connector to change the valve from top-mounted to side-mounted. Screen is moveable.

  • Manual function

    Realize regeneration immediately by pressing “Manual/Return” at any time.

  • Long outage indicator

    If outage overrides 3 days, the time of day indicator “12:12” will flash to remind people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.

  • LED dynamic screen display

    The stripes on dynamic screen flash, they indicate the control valve is in service; otherwise, it is in regeneration cycle.

  • Buttons lock

    No operations to buttons on the controller within 1 minute, button lock indicator lights on which represents buttons are locked. Before operation, press and hold the “Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.

  • It can choose all models by program selection

    When all symbols light on, press and hold “Menu/Confirm” and “Manual/Return” buttons more than 2 seconds to enter the menu of valve model selection. Press “Up”and “Down” buttons to select the requested model, then press “Menu/Confirm” button to save the selection. Reconnect the power, the model will be showed on display board.

  • Interlock function

It has a function of interlock to realize only one valve in regeneration but the other valves are in service while several valves parallel in system. In multi-steps treatment systems such as RO pre-treatment, when several valves are in series, there is only one valve in regeneration or washing to ensure pass water all the times.