Model | F116A1/A3(63505/63605) |
Regeneration | Time clock type / meter type |
Inlet/outlet | 1"M |
Drain | 3/4"M |
Brine line connector | 3/8"M |
Mounting base | 2.5" -8NPSM |
Riser pipe | 1.05"OD |
Flow rate | 4m³/h |
Water pressure | 0.15-0.6MPa |
Water temperature | 5-50℃ |
Water turbidity | <5FTU |
Relative humidity | ≤95%(25℃) |
Power adapter | Input AC100~240V/50~60HZ Output DC12V/1.5A |
F116A Automatic Multiport Softener Valves
Featuring a flow rate of 5m³/h, the F116A automatic multiport softener valve is a meter type valve and adopts a planar and corrosion resistant gasket for opening and closing. The F116A1 is a timer clock type while the F116A3 is a meter type.
Simple structure and reliable sealing
It adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse.
No water pass the valve in regeneration in single tank type.
Manual function
Realize regeneration immediately by pushing manual button at any time.
Long outage indicator
If outage overrides 3days, the time of day indicator “”will flash to remind people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.
LED dynamic screen display
The stripe on dynamic screen flash, it indicates the control valve is in service, otherwise, it is in regeneration cycle.
Buttons lock
No operations to buttons on the controller within 1 minute, button lock indicator light on which represent buttons are locked. Before operation press and hold the “Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.
It can choose time clock type or meter type by program selection
When all symbols light no, press and hold “Menu/Confirm” and “Manual/Return” buttons for 5 seconds to enter the menu of valve model selection. Please set the program type in accordance with the product type. (Tim clock type by days or hours or meter type) (Notice: The meter type product has one flow meter and flow meter cable, but the time clock type doesn’t have).
Four kinds of meter type can be selected ( Suite for F116A3, F117A3)
Model | Name | Instruction |
A-01 | Meter Delayed | Regenerate on the day although the available volume of treated water drops to zero (0). Regeneration starts at the regeneration time. |
A-02 | Meter Immediate | Regenerate immediately when the available volume of treated water drops to zero(0). |
A-03 | Meter Delayed Regeneration type, but by setting Resin Volume, Feed Water Hardness, Regeneration Factor, the controller will calculate the System Capacity. | |
A-04 | Intelligent Meter Immediate | Meter Immediately Regeneration Type, but by setting Resin Volume, Feed Water Hardness, Regeneration Factor, the controller will calculate the System Capacity. |
There are two kinds of regeneration modes for time clock type
When the program is set as time clock type by days (such as F116A1, F117A1, etc.) it can be changed to be by hours by dialing the red switch on main control board to “1” (Refer to the P14). Pointing to “ON” means the time clock type service by days.(Attention: After dialing the switch, please restart the power)
Interlock function
It has a function of interlock to realize only one valve in regeneration but the other valves are in service while several valves parallel in system. In multi-steps treatment systems such as RO pre-treatment, when several valves are in series, there is only one valve in regeneration or washing to ensure pass water all the times while different valves in regeneration or washing.