Simple structure and reliable sealing
The distribution valve adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Settling Bed, Brine Draw, Soaking, Slow Rinse, Fast Rinse and Brine Refill.
No water passes the valve during regeneration in single tank type.
Manual Function
Realize regeneration immediately by pushing “Manual/Return” at any time.
Long outage indicator
If outage overrides 3 days, the time of day indicator “12:12” will flash to remind people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.
LED dynamic screen display
The stripe on dynamic screen flash, it indicates the control valve is in service; otherwise, it is in regeneration cycle.
Button lock
No operations to buttons on the controller within 1 minute, button lock indicator light on which represent buttons are locked. Before operation press and hold the “Up”and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation
It can choose valve model through buttons.
When all symbols light on, press and hold “Manual/Return” and “Down” buttons for 2 seconds to enter the menu of valve model selection. Press “Up” or “Down” button to select the right type, and press “Menu/Confirm” to save the setting. Reconnect the power again, the display screen will show the product model that you set.
Interlock function
It has a function of interlock to realize only one valve in regeneration but the other valves are in service while several valves parallel in system. In multi-steps treatment systems such as RO pre-treatment, when several valves are in series, there is only one valve in regeneration or washing to ensure pass water all the times while different valves in regeneration or washing. (Application refer to Figure 3-9).
Remote handling input
This connector can receive external signal, used together with PLC, and computer etc. to control the valve. (Application refer to Figure3-2).
Inlet water pump connector
When the pressure of the inlet is too low, you can install inlet water pump through this connector to increase the inlet pressure. Connect the inlet of water pump with the water pipeline, connect outlet of the water pump with the inlet of the valve, so as to increase the working pressure. (Please refer the Figure 3-3/5 connect way).
Regeneration pump connector
Control the regeneration pump through this connector. Connected the inlet of the regeneration pump with soft water tank, the outlet of the regeneration pump with the inlet of electronic ball valve, connected the outlet of the electronic ball valve with the inlet of injector. When brine & slow rinse, regeneration pump opens, using softened water to regenerate. (Please refer the Figure 3-4/6 wiring connection). It is better to choose regeneration pump which flow rate is 3t/h, and the pump head is 20m.
All parameters can be modified
According to the water quality and usage, the parameters in the process can be adjusted.
Two meter types for optional (Suit for 93640B)
Mode | Name | Instruction |
A-01 | Meter Delayed | Regenerate on the day although the available volume of treated water drops to zero (0). Regeneration starts at the regeneration time. |
A-02 | Meter Immediate | Regenerate immediately when the available volume of treated water drops to zero(0). |
Maximum interval regeneration days (Suit for 93640B)
Under the situation of service reaching the setting days and the volume not yet, it could enter into regeneration process forcibly when current time is the same as regeneration time.